Product catalogue
Find the right model. Know what comes with it. Explore 50 manufacturer model references across 10 brands. Compare the specifications, save the sheet and build your enquiry.
Perkins 5 model references View models ↓ Cummins 5 model references View models ↓ LONGi 5 model references View models ↓ Huawei 5 model references View models ↓ Sunflx 5 model references View models ↓ LYTH 5 model references View models ↓ Plan before you choose
What does your power plan need? Build a load list. Explore generator capacity, solar energy and hybrid backup with assumptions you can change.
Generator Solar Hybrid
See formulas and assumptions Connected kW = sum of quantity × running watts ÷ 1,000. Daily kWh = sum of connected kW per row × daily hours. Extra starting kW = largest row’s connected kW × (starting multiplier − 1). Only the largest row starts while others run. Generator screening kVA = (connected kW + extra starting kW) ÷ assumed power factor × (1 + headroom). Solar kWp = daily kWh ÷ (peak sun hours × total yield factor). Panel count is rounded up. Hybrid continuous inverter target = connected kW × (1 + headroom). Starting peak is checked separately against the inverter’s surge duration. Nominal battery kWh = connected kW × backup hours ÷ (usable share × battery-to-AC efficiency). Generator estimates do not model starting power factor or voltage dip. Solar estimates do not model roof geometry or weather. Hybrid results do not establish compatibility, safe integration or recharge availability. LYTH NCM modules need a designed battery system; this calculator does not select a module configuration.
Technical background: Cummins application manual · PVWatts for site-specific solar modelling
JavaScript is required for live estimates. Use the buying guides or prepare your load list on the enquiry page.
Search models Filter brand All brands Perkins Cummins Yangdong LONGi Yingli Solar Jinko Solar Canadian Solar Huawei Sunflx LYTH Filter product type All product types Generator systems & engines Solar modules Solar inverters Battery modules 50 models
Family reference image
Perkins
Diesel generator engine
Typical electrical prime output 20.3 kVA / 16.2 kWe
Typical electrical standby output 22.1 kVA / 17.7 kWe
Frequency 50 Hz
Engine speed 1500 rpm Ask about this modelFamily reference image
Perkins
Diesel generator engine
Typical electrical prime output 45 kVA / 36 kWe
Typical electrical standby output 50 kVA / 40 kWe
Frequency 50 Hz
Engine speed 1500 rpm Ask about this modelFamily reference image
Perkins
Diesel generator engine
Typical electrical prime output 80 kVA / 64 kWe
Typical electrical standby output 88 kVA / 70.4 kWe
Frequency 50 Hz
Engine speed 1500 rpm Ask about this modelFamily reference image
Perkins
Diesel generator engine
Typical electrical prime output 350 kVA / 280 kWe
Typical electrical standby output 400 kVA / 320 kWe
Frequency 50 Hz
Engine speed 1500 rpm Ask about this modelFamily reference image
Perkins
Diesel generator engine
Typical electrical prime range, 50 Hz 350–500 kVA
Typical electrical standby range, 50 Hz 400–550 kVA
Frequency shown 50 Hz
50 Hz engine speed 1500 rpm Ask about this modelManufacturer reference image
Cummins
Complete diesel generator set
Prime apparent power 20 kVA
Standby apparent power 22 kVA
Prime real power 16 kW
Standby real power 18 kW Ask about this modelManufacturer reference image
Cummins
Complete diesel generator set
Prime apparent power 100 kVA
Standby apparent power 110 kVA
Prime real power 80 kW
Standby real power 88 kW Ask about this modelCummins
Complete diesel generator set
Prime apparent power 200 kVA
Standby apparent power 220 kVA
Prime real power 160 kW
Standby real power 176 kW Ask about this modelManufacturer reference image
Cummins
Complete diesel generator set
Prime apparent power 500 kVA
Standby apparent power 550 kVA
Prime real power 400 kW
Standby real power 440 kW Ask about this modelManufacturer reference image
Cummins
Complete diesel generator set
Prime apparent power 1125 kVA
Standby apparent power 1250 kVA
Prime real power 900 kW
Standby real power 1000 kW Ask about this modelFamily reference image
Yangdong
Diesel engine platform
Engine rated power at 1500 rpm 10 kW
Engine rated power at 1800 rpm 12 kW
Cylinders 3
Displacement 1.357 L Ask about this modelFamily reference image
Yangdong
Diesel engine platform
Engine rated power at 1500 rpm 11 kW
Engine rated power at 1800 rpm 13 kW
Cylinders 3
Displacement 1.532 L Ask about this modelFamily reference image
Yangdong
Diesel engine platform
Engine rated power at 1500 rpm 14 kW
Engine rated power at 1800 rpm 16 kW
Cylinders 4
Displacement 1.809 L Ask about this modelFamily reference image
Yangdong
Diesel engine platform
Engine rated power at 1500 rpm 17 kW
Engine rated power at 1800 rpm 20 kW
Cylinders 4
Displacement 2.156 L Ask about this modelFamily reference image
Yangdong
Diesel engine platform
Engine rated power at 1500 rpm 24 kW
Engine rated power at 1800 rpm 28 kW
Cylinders 4
Displacement 2.67 L Ask about this modelFamily reference image
LONGi
Solar panel
Rated power (STC) 420 W
Module efficiency (STC) 21.5%
Voltage at maximum power (STC) 32.44 V
Open-circuit voltage (STC) 38.73 V Ask about this modelFamily reference image
LONGi
Solar panel
Rated power (STC) 425 W
Module efficiency (STC) 21.8%
Voltage at maximum power (STC) 32.64 V
Open-circuit voltage (STC) 38.93 V Ask about this modelFamily reference image
LONGi
Solar panel
Rated power (STC) 430 W
Module efficiency (STC) 22.0%
Voltage at maximum power (STC) 32.84 V
Open-circuit voltage (STC) 39.13 V Ask about this modelFamily reference image
LONGi
Solar panel
Rated power (STC) 435 W
Module efficiency (STC) 22.3%
Voltage at maximum power (STC) 33.04 V
Open-circuit voltage (STC) 39.33 V Ask about this modelFamily reference image
LONGi
Solar panel
Rated power (STC) 440 W
Module efficiency (STC) 22.5%
Voltage at maximum power (STC) 33.24 V
Open-circuit voltage (STC) 39.53 V Ask about this modelFamily reference image
Yingli Solar
Solar panel
Rated power (STC) 420 W
Module efficiency (STC) 21.5%
Voltage at maximum power (STC) 31.51 V
Open-circuit voltage (STC) 38.13 V Ask about this modelFamily reference image
Yingli Solar
Solar panel
Rated power (STC) 425 W
Module efficiency (STC) 21.8%
Voltage at maximum power (STC) 31.70 V
Open-circuit voltage (STC) 38.32 V Ask about this modelFamily reference image
Yingli Solar
Solar panel
Rated power (STC) 430 W
Module efficiency (STC) 22.0%
Voltage at maximum power (STC) 31.89 V
Open-circuit voltage (STC) 38.51 V Ask about this modelFamily reference image
Yingli Solar
Solar panel
Rated power (STC) 435 W
Module efficiency (STC) 22.3%
Voltage at maximum power (STC) 32.08 V
Open-circuit voltage (STC) 38.69 V Ask about this modelFamily reference image
Yingli Solar
Solar panel
Rated power (STC) 440 W
Module efficiency (STC) 22.5%
Voltage at maximum power (STC) 32.27 V
Open-circuit voltage (STC) 38.87 V Ask about this modelFamily reference image
Jinko Solar
Solar panel
Rated power (STC) 420 W
Module efficiency (STC) 21.02%
Voltage at maximum power (STC) 32.16 V
Open-circuit voltage (STC) 38.74 V Ask about this modelFamily reference image
Jinko Solar
Solar panel
Rated power (STC) 425 W
Module efficiency (STC) 21.27%
Voltage at maximum power (STC) 32.37 V
Open-circuit voltage (STC) 38.95 V Ask about this modelFamily reference image
Jinko Solar
Solar panel
Rated power (STC) 430 W
Module efficiency (STC) 21.52%
Voltage at maximum power (STC) 32.58 V
Open-circuit voltage (STC) 39.16 V Ask about this modelFamily reference image
Jinko Solar
Solar panel
Rated power (STC) 435 W
Module efficiency (STC) 21.77%
Voltage at maximum power (STC) 32.78 V
Open-circuit voltage (STC) 39.36 V Ask about this modelFamily reference image
Jinko Solar
Solar panel
Rated power (STC) 440 W
Module efficiency (STC) 22.02%
Voltage at maximum power (STC) 32.99 V
Open-circuit voltage (STC) 39.57 V Ask about this modelFamily reference image
Canadian Solar
Solar panel
Rated power (STC) 385 W
Module efficiency (STC) 19.7%
Voltage at maximum power (STC) 30.2 V
Open-circuit voltage (STC) 36.2 V Ask about this modelFamily reference image
Canadian Solar
Solar panel
Rated power (STC) 390 W
Module efficiency (STC) 20.0%
Voltage at maximum power (STC) 30.4 V
Open-circuit voltage (STC) 36.4 V Ask about this modelFamily reference image
Canadian Solar
Solar panel
Rated power (STC) 395 W
Module efficiency (STC) 20.2%
Voltage at maximum power (STC) 30.6 V
Open-circuit voltage (STC) 36.6 V Ask about this modelFamily reference image
Canadian Solar
Solar panel
Rated power (STC) 400 W
Module efficiency (STC) 20.5%
Voltage at maximum power (STC) 30.8 V
Open-circuit voltage (STC) 36.8 V Ask about this modelFamily reference image
Canadian Solar
Solar panel
Rated power (STC) 405 W
Module efficiency (STC) 20.7%
Voltage at maximum power (STC) 31.0 V
Open-circuit voltage (STC) 37.0 V Ask about this modelFamily reference image
Huawei
Solar inverter
Rated AC output 3,000 W
Grid connection Three-phase
Maximum efficiency 98.2%
Recommended maximum PV power 4,500 Wp Ask about this modelFamily reference image
Huawei
Solar inverter
Rated AC output 4,000 W
Grid connection Three-phase
Maximum efficiency 98.3%
Recommended maximum PV power 6,000 Wp Ask about this modelFamily reference image
Huawei
Solar inverter
Rated AC output 5,000 W
Grid connection Three-phase
Maximum efficiency 98.4%
Recommended maximum PV power 7,500 Wp Ask about this modelFamily reference image
Huawei
Solar inverter
Rated AC output 6,000 W
Grid connection Three-phase
Maximum efficiency 98.6%
Recommended maximum PV power 9,000 Wp Ask about this modelFamily reference image
Huawei
Solar inverter
Rated AC output 8,000 W
Grid connection Three-phase
Maximum efficiency 98.6%
Recommended maximum PV power 12,000 Wp Ask about this modelSunflx
Off-grid solar storage inverter
Output power 4 kW
Nominal battery voltage 24 Vdc
Maximum PV array power 6000 W
Independent MPPT trackers 1 Ask about this modelSunflx
Off-grid solar storage inverter
Output power 3.6 kW
Nominal battery voltage 48 Vdc
Maximum PV array power 4000 W
Independent MPPT trackers 1 Ask about this modelSunflx
Off-grid solar storage inverter
Output power 6 kW
Nominal battery voltage 48 Vdc
Maximum PV array power 7500 W
Independent MPPT trackers 1 Ask about this modelSunflx
On/off-grid solar storage inverter
Output power 4 kW
Nominal battery voltage 24 Vdc
Maximum PV array power 2 × 4000 W
Independent MPPT trackers 2 Ask about this modelSunflx
Off-grid solar storage inverter
Output power 10 kW
Nominal battery voltage 48 Vdc
Maximum PV array power 12000 W
Independent MPPT trackers 2 Ask about this modelManufacturer reference image
LYTH
NMC battery integration module
Module nominal energy Approx. 2.55 kWh at 1C; 2.60 kWh at standard discharge
Module nominal capacity 232 Ah
Module nominal voltage 11.01 V at 1C; 11.19 V at standard discharge
Configuration 4P3S Ask about this modelManufacturer reference image
LYTH
NMC battery integration module
Module nominal energy Approx. 2.63 kWh
Module nominal capacity 234 Ah
Module nominal voltage 11.25 V
Configuration 2P3S Ask about this modelManufacturer reference image
LYTH
NMC battery integration module
Module nominal energy Approx. 2.64 kWh
Module nominal capacity 354 Ah
Module nominal voltage 7.46 V
Configuration 2P2S Ask about this modelManufacturer reference image
LYTH
NMC battery integration module
Module nominal energy Approx. 7.5 kWh
Module nominal capacity 338 Ah
Module nominal voltage 22.2 V
Configuration 2P6S Ask about this modelManufacturer reference image
LYTH
NMC battery integration module
Module nominal energy Approx. 7.5 kWh
Module nominal capacity 169 Ah
Module nominal voltage 44.4 V
Configuration 1P12S Ask about this modelNo models match. Clear the search or choose another filter.
Your next move. Your kind of power. Tell us what you need to run. Build a clear brief for the right equipment and services.
Prepare your brief ↗